29
CTC EcoLogic Pro/Family
For the property owner
4.4.1.1
Stored operation data
This menu reports the previous operating values for the
heat pump.
Total operation time h:
14196
Shows the total time the product has been powered.
Maximum primary l ow °C:
51
Shows the highest temperature supplied to the
radiators. The value may indicate the temperature
requirements of the heating circuit/house. The lower the
value during the winter period, the more suitable it is for
the heat pump’s operation.
4.4.1.2
Operation data heating circuits 2–4
This menu shows the current temperatures and
operational data for heating circuits 2, 3* and 4*, if these
are dei ned in the
Installer/Dei ned system/Heating
circuit (2–4) menus. The i rst i gure indicates the current
operational value, and the value in brackets indicates the
setpoint which the heat pump is trying to achieve.
Primary l ow 2 °C
34 (35)
Shows the temperature supplied to heating circuit 2
(sensor B2).
Heating circ pump 2
On (On/Off)
Shows the operating status of the heating circ pump
(G2).
Mixing valve 2
Opens (Opens/Closes)
Indicates whether the mixing valve (Y2) increases (opens)
or reduces (closes). Once the correct temperature has
been reached, the mixing valve’s motor then shuts down.
When additional heat (E1) is connected, the mixing valve
is used to connect the additional heat to the system (not
to heating circuit 2).
Applies to EcoLogic systems 3 and 4.
Room temperature 3 °C*
21.8 (22)
This shows the temperature registered by the room
sensor (B13) for heating circuit 3.
Primary l ow 3 °C*
37 (38)
This shows the temperature
(sensor B3)
supplied to
heating circuit 3, or the temperature brought to the fan
convector if
cooling has been dei ned (
Installer/
Dei ned
system/Cooling menu).
Settings for heatpump id:
A1
Total operation time h:
14
Maximum primary fl ow °C:
51
History oper data
Heating circuit
2-4
Primary fl ow 2 °C
34 (35)
Radiator pump 2
On
Mixing valve 2
Opens
Room temp. 3 °C
21.8 (22)
Primary fl ow 3 °C
37 (38)
Radiator pump 3
Off
Mixing valve, 3
Close
Room temp. 4 °C
21.9 (23)
Primary fl ow 4 °C
39 (40)
Radiator pump 4
Off
Mixing valve 4
Close
*Applies to the CTC EcoLogic PRO only.
Summary of Contents for CTC EcoLogic Family series
Page 2: ......
Page 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Page 67: ...67 CTC EcoLogic Pro Family For the property owner...
Page 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Page 121: ...121 CTC EcoLogic Pro Family For the installer...
Page 127: ......