12. Resistances for sensors
PT1000
Temperature ºC
Resistance Ω
Temperature ºC
Resistance Ω
-10
960
60
1232
0
1000
70
1271
10
1039
80
1309
20
1077
90
1347
30
1116
100
1385
40
1155
120
1461
50
1194
140
1535
NTC
3.3K
NTC
22K
NTC
150
Temperature
°C
Flue gas sen-
sor
Resistance Ω
Temperature
°C
Brine, HP,
Elec. Boiler,
Primary Flow,
Room Sensor
Resistance Ω
Temperature
°C
Outdoor sen-
sor
Resistance Ω
300
64
130
800
70
32
290
74
125
906
65
37
280
85
120
1027
60
43
270
98
115
1167
55
51
260
113
110
1330
50
60
250
132
105
1522
45
72
240
168
100
1746
40
85
230
183
95
2010
35
102
220
217
90
2320
30
123
210
259
85
2690
25
150
200
312
80
3130
20
182
190
379
75
3650
15
224
180
463
70
4280
10
276
170
571
65
5045
5
342
160
710
60
5960
0
428
150
892
55
7080
-5
538
140
1132
50
8450
-10
681
130
1452
45
10130
-15
868
120
1885
40
12200
-20
1115
110
2477
35
14770
-25
1443
100
3300
30
18000
-30
1883
90
4459
25
22000
-35
2478
80
6119
20
27100
-40
3289
70
8741
15
33540
60
12140
10
41800
50
17598
5
52400
40
26064
30
39517
20
61465
Summary of Contents for CTC EcoLogic Family series
Page 2: ......
Page 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Page 67: ...67 CTC EcoLogic Pro Family For the property owner...
Page 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Page 121: ...121 CTC EcoLogic Pro Family For the installer...
Page 127: ......