31
CTC EcoLogic Pro/Family
For the property owner
4.4.2.1
Heat pump status
This menu shows the current status of dei ned heat
pumps. Heat pumps A1–A10 (EcoAir, EcoAirM or
EcoPart) can have the following statuses:
Blocked in menu
The heat pump’s compressor is not permitted in the
Installer/Settings/Heat pump menu.
Communication error HP
EcoLogic cannot communicate with the heat pump.
On, DHW
The heat pump’s compressor heats the hot water tank.
Off, start delay
The heat pump’s compressor is off and is prevented
from starting due to the start delay.
Off, ready to start
The heat pump’s compressor is off and start ready.
Flow on
The heat pump and fan are started before the
compressor. Shown for EcoAir heat pumps.
On, heating
The heat pump’s compressor heats the heating circuit
.
Defrosting
The heat pump defrosts. Shown for EcoAir heat pumps.
Blocked
The heat pump has stopped due to a temperature or
pressure that has reached its maximum value.
Off, alarm
The compressor is off and gives an alarm signal.
Function test
The compressor is function tested.
The illustration above shows an example of the status for i ve dei ned
heat pumps.
Status heat pump
ID Product
Status
A1 EcoPart
On, DHW
A2 EcoPart
On, DHW
A3 EcoAir
On, heating
A4 EcoAir
Defrost
A5 EcoAir
Off, ready to start
Select ID and OK for HP start
EcoPart
EcoAir = CTC EcoAir 400
EcoAirM= CTC EcoAir 500
Summary of Contents for CTC EcoLogic Family series
Page 2: ......
Page 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Page 67: ...67 CTC EcoLogic Pro Family For the property owner...
Page 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Page 121: ...121 CTC EcoLogic Pro Family For the installer...
Page 127: ......