102
CTC EcoLogic Pro/Family
For the installer
9.3.5
CTC EcoLogic systems 4 and 5 – Cooling
If the Cooling function is deined, mixing valve Y3, charge pump G3 and
sensor B3 should be used for the cooling installation (not heating circuit
3). For details on how to connect, see the Installation and Maintenance
instructions for the cooling installation.
Pool
Buffer tank
Fan convector
9.3.6
CTC EcoLogic systems 4 and 5 – Pool
The pool can be connected in parallel with the heating circuit.
Charge pump G50 and circulation pump G51 are connected together with
sensor B50 and the heat exchanger.