114
CTC EcoLogic Pro/Family
For the installer
(G12) Charge pump 2
WILO Stratos TEC
PWM+:
blue
G48
GND:
brown
G47
GRUNDFOS UPM GEO 25-85
PWM+:
brown
G48
GND:
blue
G47
Check that the pump is correctly connected by test running it in menu
“Installer/
Service/Function test” in the control system.
10.2.4 Add heat (E1, E2, E3, E4)
The additional heat sources can be connected to the following terminal blocks:
(E1) Relay output
Relay output A8:
pole A11
(E2) 0–10 V (E2), expansion card X5*
Analogue output 0–10 V
pole 9
GND
pole 10
(E3) EcoMiniEl
Comm. 230 V
A30
NOTE!
The EcoLogic and EcoMiniEl (E3) must have a common connection to
the neutral block.
(E4) Add heat DHW
Relay output A8:
pole A13
10.2.5 Circulation Pump hot water (G40)*
230 V 1N~
The circulation pump is connected to the following terminal blocks on (G40)
Circulation pump (G4), Expansion card X6:
Phase:
pole 1
Zero:
pole 3
Earth:
pole 2
Check that the pump is correctly connected by test running it in menu
“Installer/
Service/Function test” in the control system.
10.2.6 Pump external DHW tank (G41)*
230 V 1N~
The pump is connected to the following terminal blocks:
(G41) Charge pump, expansion card (X7):
Phase:
pole 27
Zero:
pole 29
Earth:
pole 28
Check that the pump is correctly connected by test running it in menu
“Installer/
Service/Function test” in the control system.
*Applies to the CTC EcoLogic PRO only.
Summary of Contents for CTC EcoLogic Family series
Page 2: ......
Page 3: ...162 105 48 3 2016 04 08 Installation and Maintenance Manual CTC EcoLogic Pro Family...
Page 67: ...67 CTC EcoLogic Pro Family For the property owner...
Page 120: ...120 CTC EcoLogic Pro Family For the installer 11 Wiring diagram...
Page 121: ...121 CTC EcoLogic Pro Family For the installer...
Page 127: ......