Software addressing
• Software addressing takes effect when DIP switch 8 on the PROFIBUS DP terminal area
is set to "SW (on)" (factory setting).
• The address can then be configured via an operating tool (e.g. "DeviceCare" or
"FieldCare").
• The configured address is displayed in the parameter
Output/calculation → PROFIBUS
DP → Instrument address
.
Hardware addressing
Address
T
erm.
DP
of
f
on
of
f
on
SW
HW
1
2
3
4
5
6
7
8
1
2
3
4
A(N)
66
B(P)
65
Address
off
on
SW
HW
1
2
3
4
5
6
7
8
A0038436
Hardware addressing takes effect when DIP switch 8 is set to "HW (off)". When set to "on",
the position of DIP switches 1 to 7 define the following values in the address:
• Switch 1: value = 1
• Switch 2: value = 2
• Switch 3: value = 4
• Switch 4: value = 8
• Switch 5: value = 16
• Switch 6: value = 32
• Switch 7: value = 64