Emerson Process Management GmbH & Co. OHG
A-17
A
Appendix
X-STREAM XE
Short Form Manual
HASXEE-SFM-HS
05/2017
A.2 Assignment of Terminals and Sockets
A.2.1 Tabletop & Rack Mount Analyzers
A.2 Assignment of Terminals and Sockets
DC 24 V Input (
1
⁄
2
19" analyzer)
Socket X1 -
Analog outputs, relay outputs 1...5
(Assignment of screw terminals adaptor: see XSTA on next page)
Socket X4 - Digital I/O
(Assignment of screw terminals adaptor: see XSTD on next page)
Pin 1
Pin 8
Connector X2 - IOIOI - Serial Modbus interface
(Assignment of screw terminals adaptor: see XSTA on next
page)
Ethernet connector
for
Modbus
Connector X5 - Analog inputs
(Assignment of screw terminals adaptor: see XSTI on next page)
Pin no.
Signal
1
TX+
2
TX-
3
RX+
6
RX-
other
not used
Note!
Configuration of relay contacts as per standard
factory setting (NAMUR status signals). NAMUR
status signals are automatically configured Fail
Safe!
Signal
Pin
Analog
outputs
Channel 1, (+) 4 (0) - 20 mA
1
Channel 2, (+) 4 (0) - 20 mA
2
Channel 3, (+) 4 (0) - 20 mA
3
Channel 4, (+) 4 (0) - 20 mA
4
Channel 5, (+) 4 (0) - 20 mA
5
unused
6
unused
7
Relay contacts (Status signals)
Output1 (Failure) NC
8
Output1 (Failure) NO
9
Output1 (Failure) COM
10
Output3 (Off spec) NC
11
Output3 (Off spec) NO
12
Output3 (Off spec) COM
13
Pin
Signal
14
Channel 1, GND
Analog
outputs
15
Channel 2, GND
16
Channel 3, GND
17
Channel 4, GND
18
Channel 5, GND
19
unused
20
Output2 (Maintenance request) NC
Relay contacts (Status signals)
21
Output2 (Maintenance request) NO
22
Output2 (Maintenance request) COM
23
Output4 (Function check) NC
24
Output4 (Function check) NO
25
Output4 (Function check) COM
Signal
Pin
Input 1
1
Input 2
2
Input 3
3
Input 4
4
GND for all digital inputs
5
unused
6
unused
7
Output 5 NC
8
Output 5 NO
9
Output 5 COM
10
Output 6, NC
11
Output 6, NO
12
Output 6, COM
13
Output 7, NC
14
Output 7, NO
15
Output 7, COM
16
Output 8, NC
17
Output 8, NO
18
Output 8, COM
19
Digital
outputs
Digital
inputs
Pin
Signal
20
Input 5
21
Input 6
22
Input 7
23
Output 9, NC
24
Output 9, NO
25
Output 9, COM
26
Output 10, NC
27
Output 10, NO
28
Output 10, COM
29
Output 11, NC
30
Output 11, NO
31
Output 11, COM
32
Output 12, NC
33
Output 12, NO
34
Output 12, COM
35
Output 13, NC
36
Output 13, NO
37
Output 13, COM
Digital
outputs
Digital inputs
Note!
The configuration illustrated
here is that of the first socket,
labelled X4.1.
Inputs 8-14 and outputs 14-
22, are on the second socket
(X4.2), if installed.
Pin
Signal
9
Input 2 high (+)
8
Input 2 low (-)
7
Input 1 low (-)
6
Input 1 high (+)
Signal
Pin
BR 2 fit a wire bridge here to apply analog
5
BR 2 signal in current mode to input 2
*)
4
unused
3
BR 1 fit a wire bridge here to apply analog
2
BR 1 signal in current mode to input 1
**)
1
{
}
{
}
*)
alternatively set jumper P1 on electronics board XASI
**)
alternatively set jumper P2 on electronics board XASI
1: ME
2: + 24 V
3: 0 V (
⊥
)
2
1
3
Pin
6
7
8
9
Pin
1
2
3
4
5
Pin no.
MOD 485/
2 wire
MOD 485/
4 wire
RS 232
1
Common Common Common
2
not used
not used
RXD
3
not used
not used
TXD
4
not used
RXD1(+)
not used
5
D1(+)
TXD1(+) Common
6
not used
not used
not used
7
not used
not used
not used
8
not used
RXD0(-)
not used
9
D0(-)
TXD0(-)
not used