117
Reference Manual
00809-0200-4702, Rev CA
Appendix B: Product Certifications
February 2013
Product Certifications
CSA International
I6
CSA Intrinsically Safe
Certificate Number: 1143113
Applicable Standards: CAN/CSA Std. 22.2 No. 0-10, CSA Std. 22.2 No. 142-M1987,
CAN/CSA Std. 22.2 No. 157-92, CSA Std. 22.2 No. 60529:05
Markings:Ex ia; INT. SAFE FOR USE IN CL I, DIV 1, GP A, B, C, D HAZ. LOC.
TEMP CODE T3C
ENCLOSURE TYPE 4X, IP66 / IP67
FOR USE WITH EMERSON PROCESS MANAGEMENT SMARTPOWER OPTION 701PBKKF
WHEN INSTALLED PER ROSEMOUNT DWG 00702-1020
N6
CSA Class I Division 2
Certificate Number: 1143113
Applicable Standards: CAN/CSA Std. 22.2 No. 0-10, CSA Std. 22.2 No. 142-M1987, CSA
Std. 22.2 No. 213-M1987, CSA Std. 22.2 No. 60529:05
Markings:SUITABLE FOR USE IN CL I, DIV 2, GP A, B, C, D HAZ. LOC.
TEMP CODE: T3C
FOR USE WITH EMERSON SMART POWEROPTION 701PBKKF
ENCLOSURE TYPE 4X, IP66 / 67
European Certifications
I1
ATEX Intrinsic Safety
Certificate No.: Baseefa 07ATEX0239X
Applicable Standards: IEC 60079-0: 2011, EN60079-11: 2012
Markings:
II 1G Ex ia IIC T5 Ga (–60 °C
≤
Tamb
≤
+40 °C);
Ex ia IIC T4 Ga (–60 °C
≤
Tamb
≤
+70 °C)
1180
IP66 / IP67
FOR USE WITH ROSEMOUNT SMARTPOWER ™ POWER MODULE PART NUMBER
753-9220-0001, or FOR USE WITH EMERSON PROCESS MANAGEMENT SMART POWER
OPTION 701PBKKF
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – SEE INSTRUCTIONS
Switch Terminal Output
Parameter Limits Option Code 32
Fuel Sensor Terminal
Parameters Option Code 61
U
o
= 6.6 V
U
o
= 7.8 V
I
o
= 13.37 mA
I
o
= 92 mA
P
o
= 21.77 mW
P
o
= 180 mW
C
a
= 21.78 uF
C
a
= 9.2 uF
L
a
= 198 mH
L
a
= 5 mH
Switch Terminal Output Parameter Limits Option Code 22
U
o
= 6.6 V
I
o
= 26.2 mA
P
o
= 42.6 mW
C
a
= 23.8 uF
L
a
= 50 mH