13
Reference Manual
00809-0200-4702, Rev CA
Section 2: Configuration: Models 702DX22 and 702DX61
February 2013
Configuration: Models 702DX22 and 702DX61
2.5
HART menu tree
For ease of operation, changing setup, such as switch type, can be completed in several locations.
2.5.1
Dry contact inputs, measurement option code 22 (702DX22)
Figure 2-4. Field Communicator Menu Tree, DD Revision 2
1. Overview
2. Configure
3. Service Tools
1. Active Alerts
2. Communication Status
3. Discrete Input 1
4. Discrete 1 Status
5. Discrete Input 2
6. Discrete 2 Status
7. Last Update Time
8. DD Version
1. Guided Setup
2. Manual Setup
1. Alerts
2. Variables
3. Communications
4. Maintenance
5. Simulate
1. Join Device to Network
2. Configure Update Rate
3. Configure Discrete Application
4. Configure Device Display
1. Wireless
2. Discrete Sensors
3. Electronics Temperature
4. Device Information
5. Device Display
6. Other
1. Active Alerts
2. History
1. Discrete Input 1
2. Discrete 1 Status
3. Discrete Input 2
4. Discrete 2 Status
5. Electronics Temperature
6. Electronics Temperature Status
7. Supply Voltage
8. Supply Voltage Status
9. Last Update Time
1. Join Status
2. Communication Status
3. Join Mode
4. Number of Available Neighbors
5. Number of Advertisements Heard
6. Number of Join Attempts
1. Sensor Calibration
2. Other
1. Discrete 1
2. Discrete 2
3. Ambient Temperature
4. Supply Voltage
1. Clear Alert History
1. Discrete Input 1 Sensor Wiring Offset
2. Discrete Input 2 Sensor Wiring Offset
1. Perform Master Reset
2. Measurement History
3. Advertise to New Devices
4. Install New Power Module
1. Network ID
2. Join Device to Network
3. Broadcast Rates
4. Power Mode
5. Power Source
1. Configure Discrete Application
2. Discrete Input 1
3. Discrete Input 2
1. Electronics Temperature
2. Electronics Temperature Status
3. Unit
4. Maximum
5. Minimum
1. Tag
2. Long Tag
3. Device
4. Discrete Input 1
5. Discrete Input 2
6. Wireless
7. Write Protect
8. Poll Address
1. Mode
1. Write Protect
2. AC Power Filter
3. Measurement and Status Log
1. Configure Update Rate
2. Message 1
3. Message 2
4. Message 3
1. Discrete State
2. Invert Option
3. Sensor Serial Number
1. Discrete State
2. Invert Option
3. Sensor Serial Number
1. Manufacturer
2. Model
3. Final Assembly Number
4. Universal
5. Field Device
6. Software
7. Hardware
8. Descriptor
9. Message
10 Date
11 Model Number I
12 Model Number II
13 Model Number III
14 SI Unit Restriction
15 Country
16 Device ID
1. Sensor Serial Number
1. Sensor Serial Number
1. Manufacturer
2. Device Type
3. Device Revision
4. Software Revision
5. Hardware Revision