120
Reference Manual
00809-0200-4702, Rev CA
Appendix B: Product Certifications
February 2013
Product Certifications
Special conditions for safe use (X)
1.
The surface resistivity of the antenna is greater than 1 G
. To avoid electrostatic charge
build-up, it must not be rubbed or cleaned with solvents or a dry cloth.
2.
The Model 701PB Power Module may be replaced in a hazardous area. The Power
Module has surface resistivity greater than 1 G
and must be properly installed in the
wireless device enclosure. Care must be taken during transportation to and from the
point of installation to prevent electrostatic charge build-up.
SWITCH TERMINAL OUTPUT
PARAMETER LIMITS Option Code
32
FUEL SENSOR TERMINAL
PARAMETERS Option Code 61
U
o
= 6.6 V
U
o
= 7.8 V
I
o
= 13.4 mA
I
o
= 92 mA
P
o
= 21.8 mW
P
o
= 180 mW
C
i
= 0.216 uF
C
i
= 10 nF
Co
IIC
= 23.78 uF
Co
IIC
= 9.2 uF
Co
IIB
= 549.78 uF
Co
IIB
= 129 uF
Co
IIA
= 1000 uF
Co
IIA
= 1000 uF
Li=0
Li=0
Lo
IIC
= 200 mH
Lo
IIC
= 4.2 mH
Lo
IIB
= 800 mH
Lo
IIB
= 16.8 mH
Lo
IIA
= 1000 mH
Lo
IIA
= 33.6 mH
SWITCH TERMINAL OUTPUT PARAMETER LIMITS Option Code 22
U
o
= 6.6 V
I
o
= 26 mA
P
o
= 42.6 mW
C
o
= 11 uF
L
o
= 25 mH