58 Chapter 5 Parameters
EV1000 Series General Purpose Variable Speed Drive User Manual
Table 5-6 Frequency Setting Mode Selection
X3
X2
X1
Mode
OFF OFF OFF
None
OFF OFF ON Digital
setting1
OFF ON OFF
Digital
setting
2
OFF ON ON Digital
setting
3
ON
OFF
OFF
VCI analog setting
ON
OFF
ON
CCI analog setting
ON ON OFF PULSE
ON ON ON LED
keypad
25: Frequency reference is input via terminal
CCI
If the setting is 25, the frequency reference will be
input via terminal CCI forcibly. The frequency
input will be changed to the previous one if this
terminal function is disabled.
26: Not used
27: Terminal control mode is enabled
When this terminal function is enabled, the
operating command is input through this terminal
forcibly. The drive will be controlled in the
previous mode if FWD/REV terminal function is
disabled.
28
~
29: Control mode selection X1~X2
Table 5-7 Control Mode Selection
X2
X1
Control mode
OFF OFF
None
OFF ON
LED
keypad
ON OFF
Terminal
ON ON
Serial
port
The selection of control mode is realized by the
combination of ON/OFF state of any two of
X1~X5. In the above table, you should set
F7.00=28, F7.01=29.
30
~
32: MS close-loop terminal (3 terminals of
X1~X5)
Table 5-8 MS Close-loop Setting Selection
X3
X2
X1
MS close-loop reference
OFF
OFF
OFF
By F5.01
OFF
OFF
ON
MS Close-loop setting 1
OFF
ON
OFF
MS Close-loop setting 2
OF
ON
ON
MS Close-loop setting 3
ON
OFF
OFF
MS Close-loop setting 4
ON
OFF
ON
MS Close-loop setting 5
ON
ON
OFF
MS Close-loop setting 6
ON
ON
ON
MS Close-loop setting 7
The various MS close-loop setting is realized by
the combination of ON/OFF state of terminal X1
~
X3.
33: Start traverse operation
If the traverse operation is set to be manual start,
then traverse function is enabled if this function is
selected. Refer to F6.
34: Traverse reset
If traverse operation is enabled, closing the
terminal can clear the information about traverse
status no matter the drive is in auto or manual
start mode. Traverse operation continues after
this terminal is disconnected. See F6.
35: external Stop command
This Stop command is valid to all control modes.
When this function is enabled, the drive will stop
as specified F2.08.
36: Reserved
37: Prohibit drive from operating
If this function is enabled, the drive that is
operating will coast to stop and the drive ready to
run will be prohibited to start. This function is
mainly used as safety protection.
38: Reserved
39: Clear the length information
The setting of F9.15 (length) will be cleared to