![Emerson EV1000-2S0004G User Manual Download Page 122](http://html.mh-extra.com/html/emerson/ev1000-2s0004g/ev1000-2s0004g_user-manual_103363122.webp)
118 Appendix 1 Parameter Set
EV1000 Series General Purpose Variable Speed Drive User Manual
Group 8: Display Control Parameters
Para.
Name
Range
Unit Default Modification
F8.00 Accumulated
length
0~999.9km
Note: This parameter can be viewed or cleared only.
0.1km 0
○
F8.01
LED displayed
parameter selection 1
Binary code implication:
0: not displayed
1: displayed
One’s place
BIT0: output freq. (Hz) (before compensation)
BIT1: output freq. (Hz) (after compensation)
BIT2: refrerence freq. (Hz indicator blink)
BIT3: output current (A)
Ten’s place
BIT0: rotating speed (r/min)
BIT1: preset rotating speed (r/min indicator blink)
BIT2: actual line speed (m/s)
BIT3: preset line speed (m/s indicator blink)
Hundred’s place:
BIT0: output power
BIT1: output torque (
%
)
Note: if the setting is 0, the default display is
operating freq. before compensation.
1 3FF
○