![Emerson EV1000-2S0004G User Manual Download Page 132](http://html.mh-extra.com/html/emerson/ev1000-2s0004g/ev1000-2s0004g_user-manual_103363132.webp)
128 Appendix 1 Parameter Set
EV1000 Series General Purpose Variable Speed Drive User Manual
Group FH: Motor’s Parameters
Para.
Name
Range
Unit
Default
Modification
FH.00 Motor’s
poles
2
~
14
2 4
×
FH.01 Rated
power
0.4
~
999.9kW
0.1kW
Depending on model
×
FH.02 Rated
current
0.1
~
999.9A
0.1A Depending
on
model
×
FH.03 Current
without
load I
0
0.1
~
999.9A
0.1A Depending
on
model
×
FH.04 Stator
resistance
%
R1
0.00
%~
50.00
%
0.01
%
Depending on model
○
FH.05 Leakage
inductance
%
Xl
0.00
%~
50.00
%
0.01
%
Depending on model
○
FH.06 Rotor
resistance
%
R2
0.00
%~
50.00
%
0.01
%
Depending on model
○
FH.07 Mutual
inductance
%
Xm
0.0
%~
2000
%
0.1
%
Depending on model
○
FH.08 Rated
slip
frequency
0.00
~
20.00Hz
0.01Hz
0.00Hz
○
FH.09 Auto
tuning
0: disabled
1: auto tuning (motor stop)
2: auto tuning (motor
rotating)
1 0
×
FH.10 Motor
stabilization fator
0
~
255
1 Depending
on
model
○
FH.11
~
FH.21
Reserved -
-
0
*
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312