130 Appendix 1 Parameter Set
EV1000 Series General Purpose Variable Speed Drive User Manual
Group FL: Protection Parameters
Para.
Name
Range
Unit
Default
Modification
FL.05
Overload
detection
threshold
G type: 20.0
%~
180.0
%
P type: 20.0
%~
130.0
%
0.1
%
130.0
%
120.0
%
×
FL.06
Overload
alarm delay
0.0
~
60.0s
0.1s 5.0s
×
FL.07
Auto current
limiting
threshold
G type: 20.0
%~
180.0
%
P type: 20.0
%~
130.0
%
0.1
%
150.0
%
110.0
%
×
FL.08
Freq.decrease
rate rate
during current
limiting
0.00
~
99.99Hz/s
0.01Hz/s 10.00Hz/s
○
FL.09
Action mode
of auto current
limiting
0: disabled;
1: effective during acceleration or deceleration
but ineffective at constant speed, no silencing
function;
2: effective all the time, no silencing function;
3: effective during acceleration or deceleration
but ineffective at constant
speed, with silencing
function;
4: effective all the time, with silencing function.
1 2
×
FL.10
Auto reset
times
0
~
10, 0: disabled
Note: for external device fault, no auto reset
function
1 0
×
FL.11
Auto reset
interval
2.0
~
20.0s
0.1s 5.0s
×
艾默生变频器、艾默生CT高级授权代理商--广州盟雄 020-85543394 qq:2294731312