background image

 

50 

 

 

Press the 

 button to save your entries and return to the weather data screen. 

Press   to exit without saving any of your automatic settings.  

Summary of Contents for XS 1B-D

Page 1: ...System XS XS MSG2 AP Motor Control Unit XS 1B D Control Unit XS 2B Double Control Unit Installation and Operation...

Page 2: ...e batteries 19 Initial start up 20 Procedure 20 Configuring and deleting wireless connections 20 Wireless connection between motor control unit and weather station 21 Wireless connection between motor...

Page 3: ...control unit 52 The XS 1B D control unit with display 53 Assigning buttons and weather data screen display icons 53 Brightness and wind speed displays 54 Using the buttons 55 Querying service data 55...

Page 4: ...3 The XS system Connectivity installation commissioning and basic settings...

Page 5: ...automatic parameters for all individual drives The wireless based XS system is easy to install without any dirt or waste of time as there is no need to lay cables in the building The control units wo...

Page 6: ...inds only or for windows only The motors receive your automatic commands centrally from the weather station and can be individually and manually actuated using the XS 2B double control unit Required e...

Page 7: ...t on the motor control unit Setting the automatic functions for all drives using the Solexa Arexa controls see Solexa Arexa manual The described situation only allows the setting of a shade and or win...

Page 8: ...onfigured to the motor control unit in order to be able to actuate the drives M2 M3 from elsewhere in the room Required equipment Solexa or Arexa control set from software version 3 2 XS MSG2 AP motor...

Page 9: ...to the motor control unit Configuring the control units to the motor control unit Basic set up of the drives to the motor control unit using the respective XS 1B D control unit with display Setting th...

Page 10: ...oper alteration or non observance of the operating instructions will void any warranty or guarantee claim After unpacking the devices shall be checked immediately for any possible mechanical damage Th...

Page 11: ...supply an emergency generator with appropriate switching from the mains network shall also be installed on site for emergency use Settings saved in the software motor control unit and control units wi...

Page 12: ...he weather station depending on the rain amount and outdoor temperature Please also bear in mind that in the event of a power failure and rainfall external awnings will not be automatically retracted...

Page 13: ...on XS control unit battery operated Wireless communication Weather station XS MSG2 AP motor control unit Mains Motor Mains Left motor Right motor 230V AC mains power supply Motor Motor Motor Control u...

Page 14: ...for drives Left and Right connections Parallel switching of further drives from a single connection point is possible Check whether a group control relay is required by the motor manufacturer Group co...

Page 15: ...if available the technical specifications Run the power supply and drive connection cable through the grommets and connect the voltage L1 N PE and Left and Right drives PE N Up Down to the terminals d...

Page 16: ...ntrol relay for 2 drives max 1000 Drive group with a total output of less than 1000 Watt Motors with or with no integrated group control relay Drive group with a total output of less than 1000 Watt Mo...

Page 17: ...lled and used in dry interior spaces Relative air humidity must not exceed 80 Avoid condensation Rear view and drill sketch All values in mm may vary due to technical requirements Inserting the batter...

Page 18: ...ntrol unit is battery powered and communicates wirelessly with the motor control unit Avoid selecting an installation position in direct sunlight as this will result in incorrect indoor temperature me...

Page 19: ...18 Rear view and drill sketch All values in mm may vary due to technical requirements Dimensions in mm...

Page 20: ...a screwdriver directly into the slot Check that the polarity of the batteries is correct Two commercially available AA type Mignon LR6 batteries 1 5 V or rechargeable batteries 1 2 V are required Clo...

Page 21: ...ons Wireless connections may only be configured by a professional electrician as the button for configuring and deleting these is located inside the housing The wireless connections between the indivi...

Page 22: ...al operating commands every 5 seconds This transmission is indicated by a brief flash of the LED within the weather station Activate the motor control unit configure delete mode for the weather statio...

Page 23: ...r control unit stop flashing and the control unit is then configured XS MSG2 AP configure delete button Press for longer than 6 secs The LEDs on the motor control unit stop flashing All wireless conne...

Page 24: ...e delete button Press briefly three times The left hand LED is now on and the mode for configuring deleting an XS 1B D control unit on the left channel is activated Configuring a control unit with dis...

Page 25: ...Control unit set up button Press briefly once The control unit is now configured for the left channel and the LED on the motor control unit is off After configuring the wireless connection you can pro...

Page 26: ...d Down cables in the motor control unit Wireless connection between right hand channel of motor control unit and control unit with display XS MSG2 AP XS 1B D It is possible to configure an XS 1B D con...

Page 27: ...s been configured Control unit set up button Press for min 3 secs You are in Automatic settings when the screen indicates Control unit set up button Press for min 3 secs You are in Basic settings when...

Page 28: ...ally to Step 2 of the basic settings Select drive type Please refer to the following chapter Basic settings from 2 Drive types onwards Should you want to complete the basic settings at a later time pr...

Page 29: ...less connection between motor control unit and control unit with display 2 Type of drive to be controlled shades or window 3 Single or parallel operation of the drives 4 Operating position 5 Save Acce...

Page 30: ...pressing the button The changes which have been made will not then be saved If no button is pressed in Basic settings for 5 minutes the screen will automatically switch to display the temperature Any...

Page 31: ...ol unit with display To implement the basic settings or make changes skip the configuration step by pressing to confirm the displayed The display screen jumps automatically to the next step 2 Drive ty...

Page 32: ...p when these are drives of the same type The motors then actuate in parallel and only one XS 1B D control unit is required The question regarding the parallel actuation of the drives only appears when...

Page 33: ...Automatic mode For venetian blinds the opening angle of the slats can also be set reversing For windows Arexa individual positions can be set up to which the automation opens them Press the button un...

Page 34: ...no shade is provided First fully close the window using the button Then press the button to go to the next step 4 2 Setting a desired position The prompt Close will appear for a shade and Open for a...

Page 35: ...d Then press the button to complete the setting of the operating position 5 Saving the basic settings At the end of the basic settings Save will prompt you whether you want to save the settings you ha...

Page 36: ...no weather station is configured in the system no outdoor temperature wind or brightness values are displayed The control unit cannot be switched to Automatic mode Manual operation is still however po...

Page 37: ...36...

Page 38: ...37 Setting the automatic XS 1B D control unit and manual operation of the drives...

Page 39: ...r failure Once the power supply is restored the control system will be set to automatic mode The control unit and the motor control unit may no longer be manually accessed in the event of any disconne...

Page 40: ...se also bear in mind that in the event of a power failure and rainfall external awnings will not be automatically retracted if no emergency generator is installed Note that sun protection equipment ra...

Page 41: ...t parameter to be set brightness can then be seen When no weather station is configured on the system Error is displayed instead of the first parameters and no automatic settings can be applied You ca...

Page 42: ...yed in Kilolux kLux The value 1 kLux is reached already with an overcast sky at 20 kLux the sun starts being visible and 100 kLux is reached during a cloudless sky at midday The default setting for br...

Page 43: ...es can thus react rapidly to the sun Adjust the value by pressing higher and lower Then press to proceed to set the next parameter C Retraction delay After completing the setting for extension delay y...

Page 44: ...or temperature guard You can reach the settings by pressing once again when 5 C is displayed Then press to proceed to set the next parameter E Outdoor temperature guard After setting the indoor temper...

Page 45: ...n function The wind alarm protects shades which are mounted outdoors from damage If the set wind value is exceeded the awnings or blinds are retracted and manual operation is disabled Wind speed is en...

Page 46: ...shades are automatically retracted and manual operation is disabled The rain alarm remains active for 5 minutes If further rainfall is detected within these 5 minutes the alarm time will be restarted...

Page 47: ...eter to be set indoor temperature can then be seen When no weather station is configured on the system Error is displayed instead of the first parameter and no automatic settings can be applied You ca...

Page 48: ...this value is exceeded the Automatic function opens the window unless the outdoor temperature guard value drops below limit see the next parameter The default setting is 25 C Adjust the value by pres...

Page 49: ...h off the outdoor temperature guard You can reach the settings by pressing once again when 20 C is displayed Then press to proceed to set the next parameter C Wind alarm After setting the outdoor temp...

Page 50: ...you now need to select whether to switch the rain alarm on or off The rain alarm protects the fixtures from damage When it rains the window is automatically retracted and manual operation is disabled...

Page 51: ...50 Press the button to save your entries and return to the weather data screen Press to exit without saving any of your automatic settings...

Page 52: ...s No Shade B Shading when brightness exceeds kLux Extension time delay Min Retraction time delay Min Shade when indoor temperature exceeds C Outdoor temperature guard below C Wind alarm from m s Rain...

Page 53: ...second allows the drive to be precisely positioned When the button is pressed for longer than 1 second the drive will independently move to its end position Further pressing of either of the arrow but...

Page 54: ...row as well as the function mode automatic or manual battery status and current alarm messages for rain or wind Weather data is updated once per minute as well as upon any button press Outdoor temper...

Page 55: ...disabled The wind protection function can be configured and switched off in the automatic function settings for example for indoor awnings Brightness and wind speed displays When the temperature is d...

Page 56: ...nual operation using the or buttons the control system is in manual mode The automatic functions are then switched off although the rain and wind alarms are still active Press the button to once again...

Page 57: ...en a drive can be manually actuated using multiple control units it is the last received command that is always being performed This means that the operating command of a control unit is interrupted w...

Page 58: ...57 Service...

Page 59: ...wind 5 5 7 9 19 5 28 4 4 11 16 Fresh wind 8 0 10 7 28 5 38 5 5 17 21 Very fresh wind 10 8 13 8 38 6 49 7 6 22 27 Strong wind 13 9 17 1 49 8 61 5 7 28 33 Very strong wind 17 2 20 7 61 6 74 5 8 34 40 St...

Page 60: ...ess and wind speed values error messages can be displayed onscreen in the weather data display BATTERY fault Only the battery is displayed no other icons or values Manual operation is possible Cause T...

Page 61: ...ion between the weather station and the control unit is described in chapter Basic settings 1 Wireless connection motor control unit control unit Troubleshooting should only be performed by trained sp...

Page 62: ...ing should only be performed by trained specialist personnel You shall therefore please contact your installer Technical specifications The wireless frequency used is 868 2 MHz The following standards...

Page 63: ...x 1 2 V 2 AA Mignon LR6 rechargeable batteries Dimensions approx W 103 mm H 48 mm D 33 mm Ambient temperature 10 50 C Air humidity max 80 rH avoid condensation XS 1B D technical specifications Operati...

Page 64: ...lsner Elektronik GmbH Steuerungs und Automatisierungstechnik Herdweg 7 D 75391 Gechingen Germany Phone 49 0 70 56 93 97 0 Fax 49 0 70 56 93 97 20 info elsner elektronik de http www elsner elektronik d...