Settings and Service
274
17.2
Protocol management
In addition to the HACCP protocols for the expired cooking/baking and cleaning
programmes, other appliance analysis protocols for JOKER are available for the
last thirty days and can be downloaded to a USB stick. With the ProConnect
software, this data can be archived, printed or edited.
Fig. 291: Screen for
selecting the protocol type views
Protocol type
Description
HACCP
Shows the HACCP reports of the cooking, baking and
cleaning processes, sorted by day.
Consumption
Shows the consumption data of the logged cooking,
baking and cleaning processes, sorted by day.
Door
Shows how often the door has been opened and
closed.
Fault messages
Shows the occurring fault messages and warnings and
sorts them in order of occurrence.
Device properties
Display of
•
Start/end time and duration of cooking, baking
and cleaning processes
•
Software updates
•
Core temperature probe (internet/external) and
performance
Operating data
Shows operating and consumption data.
Data
Copy to USB
•
all data
•
Data of the last 7 days
Tab. 65:
Overview of possible protocol types