OVER CURRENT
The motor controller indicates a short-circuit in
the motor windings, cabling or internally in the
motor controller.
If the power is on, be very careful when wor-
king on the the machine.
Switch off the machine for at least 0 seconds to
ensure the motor controller has been completely
reset. Then try to start the machine again. If the
error returns, troubleshoot as follows:
1. Switch off the machine. Undo the contactor at X3 on
the motor. Use an ohmmeter to measure the resistance
towards the motor. Measure between 1-2, 1-3, and 2-3.
Correct resistance should be:
W4400H
W600H W850H, W1100H
cold motor 0,84 ohm 0,68 ohm
0,48 ohm
hot motor 1,1 ohm 0,9 ohm
0,6 ohm
Correct resistance
One of the resistance values is
incorrect
The motor is probably
defective.
2. Inspect the cabling from X312 on the motor controller
to X3 on the motor. Use an ohmmeter and measure the
five leads as follows:
X312:
U
V
W
T1 T2
X3:
1
2
3
7
9 (X3:4 - 6, 8 not used)
Also measure the five leads to be sure there is no short-
circuit between any two leads.
Cabling OK
Incorrect cabling
Inspect the cabling and replace
if necessary.
The motor controller output is defective.
Contactor X, female towards motor
Measure resistance between pins 1, 2, , 4,
5 and 6.
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...