151
Door and door lock
3
The door lock locks the door
When the door is closed (closed door lock
switch S), the programme unit may request
door locking by applying a voltage of 200-
240 V on door lock controller A1 input X92.
The following check is made by the A1 card
prior to locking of the door:
•
No water in drum
- input X9 from level
guard B2 is closed = 0 V
•
Motor not engaged
- input X94 from motor
control U1 open = 5 V
•
Drum not rotating
- pulse frequency on
input X95 from rotation sensor B less than
0.4 Hz.
When the above conditions are met, the card
A1 outputs a positive pulse on output X96 to
the door lock actuator, which then locks the
door. The micro switches S4a and S4b in the
actuator are closed when the door is locked.
These micro switches feed voltage to:
•
The output relays
on I/O card 1. The relays
govern the machine’s drain and water valves
as well as heater switch-on.
•
Interlock signal
for motor control (input
X02 via I/O card 1) that releases the motor
start prevention state.
Programme operation is now possible.
5225
3
Door lock
control A1
Level gu-
ard B2
M1
Door lock
A41
Programme unit
A1
X92
X4
X96
X95
X9
X5
X94
Motor
control U1
Rotation sensor B
X04
X02
X10
I/O card
A11
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...