2
Troubleshooting
List of errors, functions monitored and relevant error messages displayed, cont.
Error/Function
Error message displayed
ERROR. ERROR CODES FROM MOTOR CONTROLLER
This function includes a number of error warnings from the motor control
system for frequency-controlled motors
1 DC voltage too high
OVER VOLTAGE
Check the mains voltage.
2 DC voltage too low
UNDER VOLTAGE
Check the mains voltage.
DC level varying too much
PHASE MISSING
Check that all the fuses for the three fases are OK.
4 Short-circuit between motor windings or to earth.
OVER CURRENT
Check the isolation to ground for motor cable and motor.
6 Electronics too hot
OVERHEAT
Check the ambient temp. Check if the drum is running smoothly.
8 Power module too hot
OVERHEAT PM
Check the ambient temp. Check if the drum is running smoothly.
9 Motor thermal protection has tripped
MOTOR OVERHEAT
Check if the ventilation fan in the motor is working.
46 Overload
OVER LOAD
Check if the drum is running smoothly.
48 No communication between timer and motor control system
WATCH DOG
Check the cables between timer and motor control.
Summary of Contents for W4400H