Programme unit
1
2
3
4
5
6
7
8
9
0
Y/N
LEVEL UNBALANCE
0
LEVEL LOW
15
LEVEL MEDIUM
150
LEVEL HIGH
175
MIDDLE TEMPERATURE COOL-DOWN 70 °C
DEFAULT MOTOR ON TIME
0:12
DEFAULT MOTOR OFF TIME
0:0
FLUSH DELAY TIME
0:06
FLUSH ON TIME
0:10
BUZZER ON BUTTON
Y
MAX FILLING TIME
10:00
MAX HEATING TIME
10:00
SHOW WEIGHT TIMEOUT
0:20
PC5 BLOCKING OF HEATING
N
PC5 BLOCKING OF SPINNING
Y
HEAT 2 AS STANDARD
Y
SERVICE ALARM HOURS
Y
Flush times
Here you determine times relating to flushing clean
the supply lines of an external system for liquid
detergent: the delay time and the length of time
”on”.
Key click on
Here you determine whether or not there will be an
audible click (or beep) each time a key on the PCU
control panel is pressed.
If you answer
Yes
(Y)
:
Click (beep) for each key press.
If you answer
No (N)
:
No click or beep audible when keys pressed.
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Answer Yes (Y) or No (N).
Press .
LEVEL UNBALANCE
0
LEVEL LOW
15
LEVEL MEDIUM
150
LEVEL HIGH
175
MIDDLE TEMPERATURE COOL-DOWN 70 °C
DEFAULT MOTOR ON TIME
0:12
DEFAULT MOTOR OFF TIME
0:0
FLUSH DELAY TIME
0:06
FLUSH ON TIME
0:10
BUZZER ON BUTTON
Y
MAX FILLING TIME
10:00
MAX HEATING TIME
10:00
SHOW WEIGHT TIMEOUT
0:20
PC5 BLOCKING OF HEATING
N
PC5 BLOCKING OF SPINNING
Y
HEAT 2 AS STANDARD
Y
SERVICE ALARM HOURS
Y
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...