79
Programme unit
Outputs on I/O cards
I/O-card
I/O-card 1 A11
Connection block No. Switch No.
Function
Outputs
X4: 1
Neutral
2
1
Door lock relay, phase (normally open)
Neutral
4
1
Door lock relay, phase (normally open)
X7: 1
2
Drain 1 (Y1), phase (normally open)
2
Common neutral
2
Drain 1 (D1), phase (normally closed)
X8: 1
Heater relay (K21)
2
Neutral
X9: 1
9
Hot water inlet (Y25)
2
8
Powder 5 (Y22)
10
Powder 4 (Y14/24)
4
7
Cold water inlet (Y15)
5
6
Powder (Y1)
6
5
Powder 2 (Y12)
7
4
Powder 1 (Y11)
8
N (common neutral)
X14:1
14
Signal 4, external detergent pump
2
12
Signal , external detergent pump
1
Signal 2, external detergent pump
4
11
Signal 1, external detergent pump
5
N (common neutral)
I/O-card A1
Function
Outputs
X9: 1
Phase K42 NC to Y41A
2
Phase K41 NC to Y42A
Phase K41B and Y42B
4
Phase X972: to K4
5
Phase control unit for tilting
8
N (common)
Summary of Contents for W4400H