1
Troubleshooting
9
8
8
9
X5
590
97
X6
DOOR OPEN
No signal from the ”Door closed” during pro-
gramme operation. If the input signal for ”Door
closed” is lost during programme operation,
the OPEN DOOR error code is immediately
generated.
If the power is on, be very careful when
working on the machine.
1. Try to restart the machine (i.e. reset the error code) by
pressing START.
Error message returns
No error message
Temporary error (probably
defective contact)
2. Exit the programme using
a
. Enter the service
programme (unlock the door if it is locked). Verify
voltage supply is present between X5:4 - 5 when the
door is closed.
No voltage
Voltage present but black
square does not light
I/O card 1 A11 probably
defective.
3. Verify voltage is present between X5:3 - 5.
Voltage present
No voltage
Troubleshoot the cabling for
the voltage supply (between
the main power switch Q1
and X6).
Continued on next page
Indication
Door locked
SERVICE PROGRAM
LEVEL
2
TEMP
22°C
SPEED
0
DRAIN CLOSED
YES
EMERGENCY STOP
DOOR LOCKED
TEMPORARY PAUSE
DOOR CLOSED
OIL
REMOTE START
IMBALANCE
SERVICE
PHASE CHECK
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...