182
Weighing equipment (Optional equipment)
Menu line which should show actual weight not displayed.
Possible causes:
The option “DISPLAY WEIGHT ALLOWED” may be switched off (have the
answer “No” alongside) in “Settings 1”. Possible fault in communication
with CPU board or display. The fault can also be in the scale unit.
Fault-finding procedure:
• Check in “Settings 1” that the option “DISPLAY WEIGHT ALLOWED”
has “Yes” alongside.
• Check that the cables/wiring for CPU communication and power
supply are connected to the scale unit and in good condition.
• If the washer extractor appears to be working normally apart from the
absence of weight parameter display, try replacing the scale unit as
described under “To replace the scale unit”.
If you suspect that the weighing equipment is not displaying accurate
weight value.
Probable cause:
Probably a faulty load cell.
Fault-finding procedure:
• Place an object of known weight at one corner on top of the washer
extractor. Check the weight shown on the display. Move the weight to
each of the other corners of the machine in turn, checking the display
each time. If one corner is different from the others, this will reveal
which load cell is faulty.
• Check that the load cell in question is mechanically unobstructed, free
of anything which could affect its normal functioning.
• Replace the load cell as described under “To replace a load cell”.
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...