120
Programme unit
HEATING RELAY ON IF NOT HEATED
Y
TEMPERATURE INCREASE ALLOWED
Y
LEVEL EMPTY
90
LEVEL OVERFILL
200
PAUSE TEST LEVEL
0
PAUSE TEST TEMPERATURE
-18 °C
DEFAULT TEMPERATURE HYSTERIS
4 °C
TEMPERATURE STEP IN COOL-DOWN
4 °C
DEFAULT LOW EXTRACT TIME
00:00
DEFAULT MEDIUM EXTRACT TIME
00:00
DEFAULT HIGH EXTRACT TIME
00:00
DEFAULT DRAIN TIME
00:00
DEFAULT DISTR. TIME
00:00
DO UNBALANCE MEASUREMENT
N
DRAIN OPEN DELAY
0:1
START EXTRACT TIME
00:0
1
2
3
4
5
6
7
8
9
0
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Speed
low
medium
high
Time
Applies only to machines
with frequency-controlled
motor.
Temperature step in cool-down
Here you determine the maximum reduction in
temperature per minute during the first stage of
cool-down.
How does cool-down work?
When creating a new wash program you can,
to prevent creasing of the load, use the COOL-
DOWN module to achieve controlled cool-down
of the water in the drum. The cool-down se-
quence is divided into two stages:
1 wash temperature to middle temperature
Throughout this stage the machine will monitor
the cool-down rate, to ensure it does not exceed
the limit value you are determining here. If the
rate set is exceeded, no water will be added
until the mean value is acceptable again.
2 middle temperature to final temperature
The rate of cool-down is not monitored during
this stage. The valve opens and shuts as you
have programmed it to do.
Temp.
Time
Middle temperature
Final temperature
Temperature monitoring
HEATING RELAY ON IF NOT HEATED
Y
TEMPERATURE INCREASE ALLOWED
Y
LEVEL EMPTY
90
LEVEL OVERFILL
200
PAUSE TEST LEVEL
0
PAUSE TEST TEMPERATURE
-18 °C
DEFAULT TEMPERATURE HYSTERIS
4 °C
TEMPERATURE STEP IN COOL-DOWN 4 °C
DEFAULT LOW EXTRACT TIME
00:00
DEFAULT MEDIUM EXTRACT TIME
00:00
DEFAULT HIGH EXTRACT TIME
00:00
DEFAULT DRAIN TIME
00:00
DEFAULT DISTR. TIME
00:00
DO UNBALANCE MEASUREMENT
N
DRAIN OPEN DELAY
0:1
START EXTRACT TIME
00:0
1
2
3
4
5
6
7
8
9
0
Use the numeric keys to
enter the value.
If you make a mistake while
entering digits:
Press ERASE.
When you have finished:
Press .
Default values, extraction time
Here you determine how long the machine will
extract at the speeds low, medium and high. Later
in this section you will find the instructions for
programming the actual speeds to be used for low,
medium, high and ”turbo” extraction.
How an extraction sequence works:
In order to extract some of the water from the
load at lower speeds, the drum does not acce-
lerate to its highest speed immediately. Instead
it accelerates in several steps. This means that
the drum first accelerates to a low speed level,
remains at that for a certain time, then accele-
rates to a higher level, extracts at that speed for
a certain time, and so on until it reaches its final
(maximum) extraction speed. If you program a
low extraction speed, the number of steps at the
beginning of the extraction sequence may be
reduced.
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...