2
Control unit
External start/stop/pause (inputs)
X149: 1 start/stop, phase (mains voltage)
2 start/stop, neutral
pause, phase (mains voltage)
4 pause, neutral
External buzzer/flashlight (output)
X148: 1 phase (mains voltage)
2 neutral
"Program in progress" signal (output)
X147: 1 phase (mains voltage)
2 neutral
External detergent connections (outputs)
X146
total of 1 outputs
The terminal numbering corresponds to the
numbering used in the liquid detergent function
in programming.
X146:14 common neutral
Water recycling (outputs)
X145: 1 Drain 1 (Y1)
2 Pump 1
Stop drain (Y1b)
4 Drain 2 (Y2) (normally open)
5 Drain 2 (Y2) (normally closed)
6 Drain
7 Drain 4
8 Tank 1 water valve (Y44)
9 Tank 2 water valve (Y54)
10 Common neutral
Connectors
X100
Connector, 7 pole, CPU board
X101
Connector, 14 pole, door lock
X102
Connector, 14 pole, control unit and sensor(s) for tilt function
(optional equipment)
X10
Connector, 4 pole, speed sensor on motor
X104
Connector, 4 pole, unbalance
X105
Connector, 14 pole, water supply
X106
Connector, 14 pole, detergent supply, powder (optional equipment)
X110
Connector, 4 pole, water valve, cold, hard water (optional
equipment)
X112
Connector, 4 pole, motor fan
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...