156
Door and door lock
11
10
X95: Input from rotation sensor on motor
shaft
When the motor is operating, a pulse train is
applied on the input.
Input
Function
Pin 1:
DC 4-10 V feed
Pin 2:
0V
Pin :
DC 4-10 V pulse input
Frequency > 0.4 Hz: drum is rotating
Frequency < 0.4 Hz: drum is not rotating
X96: Output to door lock
Locks the door lock when the following condi-
tions are met:
• DC 200-240 V on input X92 (programme unit
request door locking)
• DC 0 V on input X9 (no water in drum)
• DC +5 V on input X94 (motor not activated)
• <0.4 Hz on input X95 (drum not rotating)
• No error code present
Unlocks the door lock when the following condi-
tions are met:
• DC 0 V on input X92 (programme unit request
door opening)
• DC 0 V on input X9 (no water in drum)
• DC +5 V on input X94 (motor not activated)
• <0.4 Hz on input X95 (drum not rotating)
• No error code present
Voltage
Function
DC 17-1 V, + on pin 1, - on pin 2
Unlock the door
DC 17-1 V, - on pin 1, + on pin 2
Locks the door
Door lock control A1
X95
1
2
Rotation sensor
B
X96
1
2
Door lock A41
Y80
Unlocks + -
Locks
- +
X96
X95
5184
5194
10
11
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...