77
Programme unit
X4 X5 X6 X7 X8 X9 X10 X11 X12 X1 X14 X15
X1
X2
X
X16
2 4 5 6 7 8 9 10 11 12 1 14
1
97
4
4
I/O cards
The I/O cards are controlled by the CPU card and communicate via
a serial interface. Depending on the need for inputs and outputs, one
programme unit may have one or two I/O cards.
All inputs and outputs are switched from the I/O card to the various
functions via the communication cards in the rear electric module.
Each I/O card is connected to a separate communication card: I/O
card A11 uses communication card A21 and I/O card A12 uses com-
munication card A22.
There are inputs for door lock and external switches (e.g. Start/Stop
and Pause). Signals on these inputs are passed on to the CPU card.
The outputs control water valves, detergent supply, drain and hea-
ting.
The voltage supply to the CPU and I/O cards takes place via I/O card
1 A11, which feeds voltage to both the CPU card A1 and a possible
I/O card 2 A12.
Note that if the programme unit uses two cards and one needs to be
replaced, special programming is required. It is necessary to pro-
gramme the new card with the correct I/O card number (1 or 2) using
a laptop and special software. See the section “Replacing the I/O
card”.
Red LED:
Steady red light = voltage
supply OK.
Green LED:
Quick blinks = communication between the I/O
card and CPU card is OK.
Pushbutton SW1: Used as an acknowledgement button for programming of
the order of the I/O cards (see the section “Replacing the I/O card”).
Summary of Contents for W4400H
Page 1: ...Service Manual W4400H W3600H W3850H W31100H Clarus Control 438 9206 51 06 22 ...
Page 2: ......
Page 6: ... ...
Page 14: ...14 ...
Page 18: ...18 ...
Page 64: ...64 ...
Page 72: ...72 ...
Page 146: ...146 ...
Page 164: ...164 ...
Page 166: ...166 ...
Page 185: ......
Page 186: ...www electrolux com professional Share more of our thinking at www electrolux com ...