filter cover (7). (Fig. 27)
Remove the 2 nuts (8) on the filter bracket (9) and remove the filter (10).
At Point B (on the sides (11), remove the 2 nuts (12), washers (13), release the filter bracket
(14) and remove the filter (15).
Clean or wash the filters, if heavily contaminated, in a solution of soapy water and allow to
dry completely.
Reinstall the filters once dry (reverse the procedure to reassemble).
Fig. 27: Compressor inlet filter cleaning/replacement
17.9. Compressor performance check
Turn off the compressor using the STOP button.
Vent the air pressure in the air tank to zero.
Turn on the compressor using the START button.
Measure the time to fill the air tank from 0 to 7 bar.
The measured value must be less than the data provided in the “Technical Data” table.
17.10. Check of non-return valve operation
Compressed air line:
Check for the proper operation of all non-return valves in the compressed air line and the
disconnection of pressure hoses from air pumps.
One aggregate must be running at all times, while the others may be shut off
using the current protection device in the switchboard. No compressed air may
leak from the check valves.
Summary of Contents for DK50 4x4VRT/M
Page 1: ...DK50 4x4VRT M DK50 6x4VRT M User manual...
Page 2: ......
Page 4: ...CONTENTS 5...
Page 11: ...PRODUCT DESCRIPTION 03 2021 11 NP DK50 Nx4VRTM AD A EN 4_03 2021 DK50 4x4VRTS M DK 50 6x4VRT M...
Page 15: ...PRODUCT DESCRIPTION 03 2021 15 NP DK50 Nx4VRTM AD A EN 4_03 2021 Fig 1 Compressor with dryer...
Page 36: ...INSTALLATION NP DK50 Nx4VRTM AD A EN 4_03 2021 36 03 2021 DK50 6x4VRT M DK50 6x4VRTS M...
Page 68: ...ANNEX NP DK50 Nx4VRTM AD A EN 4_03 2021 68 03 2021 ANNEX 21 MAPPING PARAMETERS...
Page 69: ...ANNEX 03 2021 69 NP DK50 Nx4VRTM AD A EN 4_03 2021...
Page 71: ......
Page 72: ......
Page 73: ......