INSTALLATION
NP-DK50-Nx4VRTM-AD-A-EN-4_03-2021
32
03/2021
Fig. 20: Air pump controls
A
– motors M1-M3
B
– motors M4-M6
UL
– upper limit
BL
– bottoms limit → Master = 6.2, SLAVE = 6.0
Description of adsorption dryer solenoid valve control
The inlet valves (Inlet A and B) switch every 120 seconds.
The regeneration valves open variably based on the real load, e.g. if all motors are running, flushing
is set to 110 seconds, while if one trio set is running, flushing is set to 55 seconds.
Fig. 21: Solenoid valve diagram