16. SWITCHING OFF THE COMPRESSOR
Use the main switch, Q10, to switch off the compressor for maintenance or other reasons; the switch
also functions as a central stop button. The compressor is disconnected from the mains with the
exception of the mains terminal block X0.
Vent the air tank by disconnecting from the central compressed air circuit and opening the outlet
valve (Fig. 14) or the drain valve.
Power terminals X0 remain energised even when main switch Q10 is in the “O”
(off) position.