PRODUCT MAINTENANCE
03/2021
59
NP-DK50-Nx4VRTM-AD-A-EN-4_03-2021
Fig. 31: Venting pressure from the cooler and condensate separator
The process of manually venting pressure from the equipment is complete after approximately 2
minutes.
17.16.
Replacement of the dryer’s internal filters
Working with pressurised pneumatic components poses a risk of injury.
Prior to any work, disconnect the equipment from the mains, shut off the
compressor and vent all pressure in the equipment to zero.
In normal operation, filter replacement must be performed in the upper part of the dryer at the
defined interval.
Turn off the compressor.
Check the pressure in the dryer.
If the dryer chambers are under pressure,
proceed in accordance with Chapter
17.15.
Unscrew the 8 screws (1).
Disassemble the outlet panel (2) on which
the filters (3) are mounted.
Unscrew the dirty filters (3) and replace
with new filters.
Check the seal (4) on the bottom of the
outlet module and replace if necessary.
Reverse the procedure to reassemble.
Switch on the compressor.
Check for any dryer leaks.
Fig. 32: Replacement of internal filters
17.17. Replacement of cassettes with adsorbent media
In normal operation, the replacement of the cassettes with adsorbent media must be performed at
the defined interval.
Summary of Contents for DK50 4x4VRT/M
Page 1: ...DK50 4x4VRT M DK50 6x4VRT M User manual...
Page 2: ......
Page 4: ...CONTENTS 5...
Page 11: ...PRODUCT DESCRIPTION 03 2021 11 NP DK50 Nx4VRTM AD A EN 4_03 2021 DK50 4x4VRTS M DK 50 6x4VRT M...
Page 15: ...PRODUCT DESCRIPTION 03 2021 15 NP DK50 Nx4VRTM AD A EN 4_03 2021 Fig 1 Compressor with dryer...
Page 36: ...INSTALLATION NP DK50 Nx4VRTM AD A EN 4_03 2021 36 03 2021 DK50 6x4VRT M DK50 6x4VRTS M...
Page 68: ...ANNEX NP DK50 Nx4VRTM AD A EN 4_03 2021 68 03 2021 ANNEX 21 MAPPING PARAMETERS...
Page 69: ...ANNEX 03 2021 69 NP DK50 Nx4VRTM AD A EN 4_03 2021...
Page 71: ......
Page 72: ......
Page 73: ......