TECHNICAL DATA
03/2021
17
NP-DK50-Nx4VRTM-AD-A-EN-4_03-2021
TECHNICAL DATA
Compressors are designed for operation in dry, ventilated and dust-free indoor rooms under the
following climactic conditions:
Temperature
+5°C to +40°C
Relative humidity
max. 70%
Working pressure 6
– 8 bar
DK50
4x4VRT/M
DK50
4x4VRTS/M
DK50
6x4VRT/M
DK50
6x4VRTS/M
Rated voltage
Frequency
a)
V, Hz
3x400, 50
3x400, 50
3x400, 50
3x400, 50
Output at 6 bar (FAD) at
PDP-
20°C
l/min.
900
900
1350
1350
Output at 6 bar (FAD) at
PDP-
40°C
l/min.
860
860
1290
1290
Working pressure
b)
bar
6.0
– 8.0
6.0
– 8.0
6.0
– 8.0
6.0
– 8.0
Max. current
A
22
22
29
29
Main circuit protection
device rating
A
25
25
32
32
Main electrical feeder
mm
2
4
4
6
6
Enclosure
IP10
IP30
IP10
IP30
Motor output
kW
2.2
2.2
2.2
2.2
Air tank capacity
l
500
500
500
500
Air quality
– filtration
m
-
-
-
-
Maximum operating
pressure of safety valve
bar
10.0
10.0
10.0
10.0
Noise at 5 bar (L
pA
)
dB
≤80
≤70
≤83
≤72
Operating mode
%
S1-100
S1-100
S1-100
S1-00
PDP drying
performance at 7 bar
d)
°C
-20
-40
-20
-40
-20
-40
-20
-40
Time to fill air tank from
0 to 7 bar
s
150
150
115
115
Net weight
c)
kg
439
572
531
664
Weight - compressor
module
kg
268
401
350
483
Weight - dryer module
kg
44
44
54
54
Weight of air tank
kg
127
127
127
127
Net dimensions
W x L x H
mm
2875 x 2090 x
705
2875 x 2090 x
705
2875 x 2090
x 705
2875 x 2090 x
705
Dimensions -
compressor module
(W x L x H)
mm
1235 x 1720 x
630
1235 x 1755 x
705
1235 x 1720
x 630
1235 x 1760 x
705
Dimensions
– dryer
module
mm
530 x 965 x
350
530 x 965 x
350
530 x 1310 x
350
530 x 1310 x
350
Air tank dimensions
(W x L x H)
mm
730 x 2090 x
705
730 x 2090 x
705
730 x 2090 x
705
730 x 2090 x
705
Required cooling air
changes in space
m
3
/h
2250
2250
3000
3000
Summary of Contents for DK50 4x4VRT/M
Page 1: ...DK50 4x4VRT M DK50 6x4VRT M User manual...
Page 2: ......
Page 4: ...CONTENTS 5...
Page 11: ...PRODUCT DESCRIPTION 03 2021 11 NP DK50 Nx4VRTM AD A EN 4_03 2021 DK50 4x4VRTS M DK 50 6x4VRT M...
Page 15: ...PRODUCT DESCRIPTION 03 2021 15 NP DK50 Nx4VRTM AD A EN 4_03 2021 Fig 1 Compressor with dryer...
Page 36: ...INSTALLATION NP DK50 Nx4VRTM AD A EN 4_03 2021 36 03 2021 DK50 6x4VRT M DK50 6x4VRTS M...
Page 68: ...ANNEX NP DK50 Nx4VRTM AD A EN 4_03 2021 68 03 2021 ANNEX 21 MAPPING PARAMETERS...
Page 69: ...ANNEX 03 2021 69 NP DK50 Nx4VRTM AD A EN 4_03 2021...
Page 71: ......
Page 72: ......
Page 73: ......