TECHNICAL DATA
03/2021
19
NP-DK50-Nx4VRTM-AD-A-EN-4_03-2021
Working pressure 8
– 10 bar
DK50
4x4VRT/M
DK50
4x4VRTS/M
DK50
6x4VRT/M
DK50
6x4VRTS/M
Rated voltage
Frequency
a)
V, Hz
3x400, 50
3x400, 50
3x400, 50
3x400, 50
Output at 8 bar (FAD) at
PDP-
20°C
l/min.
690
690
1040
1040
Output at 8 bar (FAD) at
PDP-
40°C
l/min.
650
650
980
980
Working pressure
b)
bar
8.0
– 10.0
8.0
– 10.0
8.0
– 10.0
8.0
– 10.0
Max. current
A
23
23
30
30
Main circuit protection
device rating
A
25
25
32
32
Main electrical feeder
mm
2
4
4
6
6
Enclosure
IP10
IP30
IP10
IP30
Motor output
kW
2.2
2.2
2.2
2.2
Air tank capacity
l
500
500
500
500
Air quality
– filtration
m
-
-
-
-
Maximum operating
pressure of safety valve
bar
11.0
11.0
11.0
11.0
Noise at 5 bar (L
pA
)
dB
≤80
≤70
≤83
≤82
Operating mode
%
S1-100
S1-100
S1-100
S1-00
PDP drying
performance at 7 bar
d)
°C
-20
-40
-20
-40
-20
-40
-20
-40
Time to fill air tank from
0 to 7 bar
s
150
150
115
115
Net weight
c)
kg
439
572
531
664
Weight - compressor
module
kg
268
401
350
483
Weight - dryer module
kg
44
44
54
54
Weight of air tank
kg
127
127
127
127
Net dimensions
W x L x H
mm
2875 x 2090 x
705
2875 x 2090 x
705
2875 x 2090
x 705
2875 x 2090 x
705
Dimensions -
compressor module
(W x L x H)
mm
1235 x 1720 x
630
1235 x 1755 x
705
1235 x 1720
x 630
1235 x 1760 x
705
Dimensions
– dryer
module
mm
530 x 965 x
350
530 x 965 x
350
530 x 1310 x
350
530 x 1310 x
350
Air tank dimensions
(W x L x H)
mm
730 x 2090 x
705
730 x 2090 x
705
730 x 2090 x
705
730 x 2090 x
705
Required cooling air
changes in space
m
3
/h
2250
2250
3000
3000
a)
Specify the compressor version when ordering
b)
Consult any other range of pressure with the supplier
c)
Weight is indicative and only applies to the product without accessories
d)
Applies to ambient temperatures of <30°C PDP – pressure dew point
Summary of Contents for DK50 4x4VRT/M
Page 1: ...DK50 4x4VRT M DK50 6x4VRT M User manual...
Page 2: ......
Page 4: ...CONTENTS 5...
Page 11: ...PRODUCT DESCRIPTION 03 2021 11 NP DK50 Nx4VRTM AD A EN 4_03 2021 DK50 4x4VRTS M DK 50 6x4VRT M...
Page 15: ...PRODUCT DESCRIPTION 03 2021 15 NP DK50 Nx4VRTM AD A EN 4_03 2021 Fig 1 Compressor with dryer...
Page 36: ...INSTALLATION NP DK50 Nx4VRTM AD A EN 4_03 2021 36 03 2021 DK50 6x4VRT M DK50 6x4VRTS M...
Page 68: ...ANNEX NP DK50 Nx4VRTM AD A EN 4_03 2021 68 03 2021 ANNEX 21 MAPPING PARAMETERS...
Page 69: ...ANNEX 03 2021 69 NP DK50 Nx4VRTM AD A EN 4_03 2021...
Page 71: ......
Page 72: ......
Page 73: ......