142
P/N 120413
01/05
System Setup
PresencePLUS
®
P4 EDGE
Banner Engineering Corp.
• Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Strobe Tab
The Strobe option in the System Setup window is shown below. Use the
Strobe
tab to set the strobe signal (Pin 4 on the
external light connector) for a strobed light source. The strobe signal is a +5V dc TTL signal.
---------------------------------------------------------------------------------------------------
System Setup Window Strobe Tab
Strobe Width
Level
Strobe Width Selections in the Strobe Tab of the System Setup Window
Selection
Description
OFF
The strobe output never becomes active.
ON
The strobe output remains active.
Exposure Duration
The strobe output is active only while the Sensor is acquiring an image.
Time Duration
Sets the duration for active strobe output from the initial valid trigger (minimum pulse width has been satisfied) to
the end of the duration. The range is from 0 to 4,000 ms.
Level Selections in the Strobe Tab of the System Setup Window
Selection
Description
Active High
An active output produces a +5V dc signal.
Active Low
An active output produces a 0V dc signal.
Default
Default
Time Duration range = 1 – 4,000 ms