132
P/N 120413
01/05
Run
PresencePLUS
®
P4 EDGE
Banner Engineering Corp.
• Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Product Change and Product Select Timing Diagram
--------------------------------------
Failed Image Hold (default: 1 second)
Enter how many seconds failed images should be displayed on the optional NTSC
video monitor.
Trigger Delay Adjust (default: 0 ms)
Enter how long (in ms) to delay the Sensor before it takes a picture after receiving a
valid trigger.
Using the Trigger Delay when a part is triggered too early may be easier than moving the Sensor.
Start counting pulses on
Product Select line.
Pulse this line to increment
the inspection address.
Stop counting pulses on
Product Select line.
Pulse not counted
NOTES:
•
The minimum pulse width on Product Select is 1 millisecond active and 1 millisecond inactive.
•
In this example, the Sensor will stop executing the inspection it is currently running, go to address number four
(because there are four pulses), load the inspection at location four, enter Run mode, and execute the inspection on
the next valid trigger.
•
If the Sensor is in Run mode, the Product Change line should be activated only when the Sensor is Ready (Green
Ready LED is ON). If the Product Change line is activated when the Sensor is in Run mode but performing an
inspection (not Ready), the current inspection will be aborted, and the Sensor will proceed to load the inspection at the
indicated address.
•
If the Product Change line is activated when the Sensor is not in Run mode (Setup mode, for example), then the
Sensor will go to the address indicated (address number four in this case) and begin executing.
•
The maximum number of pulses is limited by the number of inspections possible on the Sensor.
Product Change Input
Product Select Input
Not Active
Not Active
Active
Active
Pulse
1
Pulse
2
Pulse
3
Pulse
4
TIP