Teach
Banner Engineering Corp.
• Minneapolis, MN USA
www.bannerengineering.com • Tel: 763.544.3164
Teaching an Inspection
Teaching on a number of known good samples finds acceptable variations and automatically sets the judgment tolerances to
accommodate the full range of acceptable results.
Several Teach parameters may be selected in the
Teach Tool
tab, such as how many images to consider during a teaching
session and what type of captured images to display.
-----------------------------------------------------------------------------------------
Teach Tool Tab
Sample Size (default: All)
-
Use
All
to not limit the Teach sample size.
-
Use
Count
to have the Sensor automatically stop the Teach process after a set
number of samples.
Use the Count option when there is a known sample set size. Use the arrows to
increase or decrease the sample size. When the sample size is reached, the
Sensor will stop the Teach process, and the
Start/Stop
button will return to
displaying
Start
.
Trigger (default: External)
The Sensor must receive an external trigger (Pin 3) to accept a sample.
To teach an inspection:
Set preferences from the various Teach options, and click the
Start
button.
The
Start
button turns into a
button after it is
clicked.
Options are explained in the following table.
To stop teaching an inspection:
Click the
Stop
button.