Chapter 26
| CFM Commands
Continuity Check Operations
– 798 –
show ethernet cfm
errors
This command displays the CFM continuity check errors logged on this device.
Syntax
show ethernet cfm errors
[
domain
domain-name
|
level
level-id
]
domain-name –
Domain name. (Range: 1-43 alphanumeric characters)
level-id
– Authorized maintenance level for this domain. (Range: 0-7)
Default Setting
None
Command Mode
Privileged Exec
Example
Console#show ethernet cfm errors
Level VLAN MPID Interface Remote MAC Reason MA Name
----- ---- ---- --------- ----------------- ---------------- ----------------
5 2 40 Eth 1/1 ab.2f.9c.00.05.01 LEAK provider_1_2
Console#
Table 161: show ethernet cfm errors - display description
Field
Description
Level
Maintenance level associated with this entry.
VLAN
VLAN in which this error occurred.
MPID
Identifier of remote MEP.
Interface
Port at which the error was recorded
Remote MAC
MAC address of remote MEP.
Reason
Error types include:
LEAK – MA
x
is associated with a specific VID list
*
, one or more of the VIDs
in this MA can pass through the bridge port, no MEP is configured facing
outward (down) on any bridge port for this MA, and some other MA
y
, at a
higher maintenance level, and associated with at least one of the VID(s)
also in MA
x
, does have a MEP configured on the bridge port.
VIDS – MA
x
is associated with a specific VID list
on this MA on the bridge
port, and some other MA
y
, associated with at least one of the VID(s) also
in MA
x
, also has an Up MEP configured facing inward (up) on some bridge
port.
EXCESS_LEV – The number of different MD levels at which MIPs are to be
created on this port exceeds the bridge's capabilities.
OVERLAP_LEV – A MEP is created for one VID at one maintenance level,
but a MEP is configured on another VID at an equivalent or higher level,
exceeding the bridge's capabilities.
* This definition is based on the IEEE 802.1ag standard. Current software for this switch only supports a single
VLAN per MA. However, since it may interact with other devices which support multiple VLAN assignments per
MA, this error message may be reported.
MA
The maintenance association for this entry.
Summary of Contents for ECS4120-28F
Page 36: ...Contents 36...
Page 38: ...Figures 38...
Page 46: ...Section I Getting Started 46...
Page 70: ...Chapter 1 Initial Switch Configuration Setting the System Clock 70...
Page 86: ...Chapter 2 Using the Command Line Interface CLI Command Groups 86...
Page 202: ...Chapter 5 SNMP Commands Additional Trap Commands 202...
Page 210: ...Chapter 6 Remote Monitoring Commands 210...
Page 216: ...Chapter 7 Flow Sampling Commands 216...
Page 278: ...Chapter 8 Authentication Commands PPPoE Intermediate Agent 278...
Page 360: ...Chapter 9 General Security Measures Port based Traffic Segmentation 360...
Page 384: ...Chapter 10 Access Control Lists ACL Information 384...
Page 424: ...Chapter 11 Interface Commands Power Savings 424...
Page 446: ...Chapter 13 Power over Ethernet Commands 446...
Page 456: ...Chapter 14 Port Mirroring Commands RSPAN Mirroring Commands 456...
Page 488: ...Chapter 17 UniDirectional Link Detection Commands 488...
Page 494: ...Chapter 18 Address Table Commands 494...
Page 554: ...Chapter 20 ERPS Commands 554...
Page 620: ...Chapter 22 Class of Service Commands Priority Commands Layer 3 and 4 620...
Page 638: ...Chapter 23 Quality of Service Commands 638...
Page 772: ...Chapter 25 LLDP Commands 772...
Page 814: ...Chapter 26 CFM Commands Delay Measure Operations 814...