Alarms and Messages of VS 300
154
Doku-Version 2.05 - Firmware 2.10 - 15. September 2017
10.3 Messages / alarms in the VS 300
Z
N
R
.
51203
50
9
30
E
S
C
RE
S
ET
1
2
3
4
1
2
5
6
8
9
1
0
11
12
7
S
tatus
1
2
O
FF
/
/
O
FF
(2)
Message/alarm code shown on display - process fault report
E212
in this example
These message/alarm codes can be displayed in more detail by opening Parameter List F on the integral user
interface. Faults and messages/alarms occurring are displayed in two ways:
1.
In basic display mode:
The respectively most recent message is indicated in basic display mode by its
associate fault code (
E001
−
E246
, see section NO TAG Process Fault Reports or System Fault Reports
for details). The alarm/message LED flashes. Pressing the ESC/RESET key quit the display and returns to
displaying control loop actual temperature. When the message is no longer current or when no more faults
are effective, press the ESC/RESET (longer than 5 sec.) to cancel the message and delete it from the fault
report memory.
2.
In message display mode:
From Parameter List F you can change to message display mode. On press
ing the
↵
key while in Parameter List F,
F001
is displayed if a message is current, meaning not yet can
celled. This indicates the most recent message. Use the
↑
key to move to the preceding messages (
F002
to max.
F100
). If no messages exist, '- - - -' is shown on the display.
Messages/alarms that are still active are shown flashing to distinguish them from inactive messages/
alarms.
Pressing the
↵
key again in message/alarm display mode (
F002 -
max.
F100
) displays details for the se
lected message/alarm. Message/alarm details consist of the message/alarm code (
E001 - E246
, see sec
tion 8 Process Fault Reports and System Fault Reports for details), message/alarm status (
0
or
1
), incom
ing time stamp (date-year-time) and outgoing time stamp (date-year-time).
These message/alarm details can be interrogated with the
↑
and
↓
keys. The relay/control stage status
LEDs indicate which message/alarm detail is currently displayed. For example, the day date (15th) of the
incoming time stamp is shown in the illustration above.
Summary of Contents for VS 300
Page 8: ...vi Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 18: ...System Design of VS 300 10 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 22: ...Application of VS 300 14 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 160: ...Decommissioning and disposal 152 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 166: ...Alarms and Messages of VS 300 158 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 170: ...162 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...