Parameter List and Menu Structure of VS 300
108
Doku-Version 2.05 - Firmware 2.10 - 15. September 2017
8.1.10 Parameter List S3: Basic Settings System Configuration
Parameter
No.
Function /
Description
Range
Default
Dim.
Displayed /
Condition
NT
LT
HP
S390
Select controller confi
guration
0: CL1 = LT control
CL2 = LT control
-
-
-
-
Requires Superuser mode ac
cess rights
(Parameter
A060 = 10
)
1: CL1 = LT control
CL2 = NT control
2: CL1 = LT control
CL2 = HP control
3: CL1 = NT control
CL2 = NT control
4: CL1 = NT control
CL2 = HP control
5: CL1 = HP control
CL2 = HP control
6: CL1 = NT control
CL2 = LT control
S391
Load default settings
0: Preserve existing settings
1: Load default settings
0
0
0
-
S392
Parameter backup
0: No parameter backup
1: Back up parameters
0
0
0
-
S393
Delete run time archi
ves
0: Preserve archives
1: Delete archives
0
0
0
-
S394.1[1]..
S394.[m]
und
S394.[n]..
S394.[o]
Reset operating hours
for relay stages 1 - 12
1)
0: Preserve operating hours
1: Reset operating hours to 0
-
-
-
-
Requires Superuser mode ac
cess rights
(Parameter
A060 = 10
)
CL1:
S301 > 0
[m]=
Basic configuration (<=4):
[
Value S301
]
1st expansion stage (<=8):
[
Value S301
]
2nd expansion stage (<=12):
[
Value S301
]
or
CL1:
S331 > 0
[n]=
Value S301
] + 1
[0]=
Basic configuration (<=4):
[n] + [
Value S331
]
1st expansion stage (<=8):
[n] + [
Value S331
]
2nd expansion stage (<=12):
[n] + [
Value S331
]
1)
Maximum values varying with expansion stage/Number of relay stages can be 4/8/12
Summary of Contents for VS 300
Page 8: ...vi Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 18: ...System Design of VS 300 10 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 22: ...Application of VS 300 14 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 160: ...Decommissioning and disposal 152 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 166: ...Alarms and Messages of VS 300 158 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 170: ...162 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...