Pin and Terminal Assignments of VS 300
76
Doku-Version 2.05 - Firmware 2.10 - 15. September 2017
6.1
View of connecting terminals
As described in section 1 System Configuration, the VS 300 Pack Controller is of modular design. The following
view of pin and terminal assignments describes the VS 300 with all expansion stages and add-on modules fit
ted.
Rear of VS 300: Position of connecting terminals (all expansion stages and add-on modules fitted)
TTY
ANALOG
OUT
ALAR
M
R
E
LAY
2
30 V
AC
2
8
2
6
25
18
16
1
5
R
E
LAY OUTPUT
S
2
30 V
AC
TEMP. INPUTS
NTC / PT1000
96
9
5
88
86
8
5
78
76
7
5
108
106
10
5
98
Z42
Z41
Z32
Z31
Z22
Z21
Z12
Z11
Z62
Z61
Z52
Z51
136
13
5
1
2
8
1
2
6
1
25
118
116
11
5
1
4
8
1
4
6
1
45
138
5
6
55
4
8
4
6
45
3
5
38
36
68
66
6
5
5
8
ZNR. 51203 50
6
30 E3
B
A
SI
C
CON
FI
GURAT
I
ON
FI
R
S
T
EX
PAN
SI
ON
S
TAG
E (optionally)
SE
COND
EX
PAN
SI
ON
S
TAG
E (optionally)
ALAR
M
R
E
LAY
M
ODUL
E
(
(
OPT
I
ONALLY
)
ALAR
M
ACT
IV: 1
5
,16)
TTY
I
NT
E
R
F
AC
E
AN
S
ANALOG
OUTPUT
S
CAN
B
U
S M
ODUL
E
(
OPT
I
ONALLY
)
CAN
B
U
S
ADR
ESS
SE
L
E
CTOR
SWI
TC
H
R
E
LAY
/
CONTROL
S1..S
4
R
E
LAY
/
CONTROL
S
5
..S8
R
E
LAY
/
CONTROL
S9..S1
2
ADDR
ESS
CAN
-B
U
S
D
I
G
I
TA
L
2
30 V
AC
1
4
2
3
1
A4
1
A42
A5
1
A52
1
2
3
4
D
31
D
3
2
D4
1
D42
D
1
2
D
11
D2
1
D22
A
1
2
A22
A
3
2
A2
1
A
11
A
31
5
0
2 3
1
4
6
7
8
9
TTY
ANALOG
I
N
|
ANALOG
OUT
S
UPPLY
2
30 V
AC
L
N
1
4
13
F
RONT
PAN
E
L
SWI
TC
H
PO
WE
R
S
UPPLY
2
30 V
AC
P
E
(M
4
)
D
31
D
3
2
D4
1
D42
D
1
2
D
11
D2
1
D22
A
1
2
A22
A
3
2
A2
1
A
11
A
31
D
in 1
D
in
2
D
in 3
D
in
4
2
30V
AC
2
30V
AC
A
in 1 +
A
in 1
4
-
2
0m
A
A
in 3 +
A
in 3
4
-
2
0m
A
A
in
2
+
A
in
2
4
-
2
0m
A
D
I
G
I
TAL
I
NPUT
S
ANALOG
I
NPUT
S
2
8
2
6
25
18
16
1
5
P
rio 1
P
rio
2
A4
1
A42
A5
1
A52
1
2
3
4
A
out 1 +
A
out 1
GND
A
out
2
+
A
out
2
GND
0-10V
R
x
D
GND
T
x
D
GND
TTY
Schirm
GND
CAN
-
L
CAN
-H
0-10V
4
2
3
1
5
0
2 3
1
4
6
7
8
9
136
13
5
1
2
8
1
2
6
1
25
118
116
11
5
1
4
8
1
4
6
1
45
138
S9
S10
S11
S1
2
96
9
5
88
86
8
5
78
76
7
5
108
106
10
5
98
S
5
S6
S7
S8
5
6
55
4
8
4
6
45
3
5
38
36
68
66
6
5
5
8
S1
S
2
S3
S
4
1
4
13
L
N
SWI
TC
H
Attention is required to the following items when installing and connecting wiring:
All connecting leads from and to the VS 300 - except digital inputs and relay outputs - must be
screened in order to rule out faulty measurements and other malfunctions.
Correct polarity must be ensured on inputs and outputs with a current or voltage interface (0-10 V or
4-20 mA). Short circuiting or incorrect signal or power input can result in impairment of function or
even in destruction of VS 300 components. Always disconnect the system from power before mak
ing or separating connections on the VS 300.
Summary of Contents for VS 300
Page 8: ...vi Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 18: ...System Design of VS 300 10 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 22: ...Application of VS 300 14 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 160: ...Decommissioning and disposal 152 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 166: ...Alarms and Messages of VS 300 158 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...
Page 170: ...162 Doku Version 2 05 Firmware 2 10 15 September 2017 Notice ...