User Manual The1.1 version of 2018 Guangzhou EC-PACK CO.LTD
57
7.11.
Monitor Jet
This groups together the ink and solvent control parameters on a single screen. The parameters are
displayed only; they cannot be changed by the user.
Pressure
The pressure currently set on the pressure DAC (same as Set Pressure)
VOD
The most perfect VOD value should equivalent to the Ref VOD. It will not influence the printing
quality if the VOD is near the Ref VOD.
NOTE: The warning “No VOD readings” will be displayed on the status line when a valid VOD
has not been obtained for 15 minutes. The warning will be redisplayed every 15 minutes while no
VOD readings as obtained.
Modulation
The current modulation voltage.
Phase
The system will load the phase automatically when it is On. And unload when Off.
Add Solvent
When Press (Set Pressure) exceeds this value, solvent will be automatically added by the printer.
Ref. VOD
The reference VOD as input with the printhead code.
Ref. MOD
The reference modulation determined by the last print head calibration or set by the user (same as
Ref Modulation in the SETUP menu).
Read Press
The current read pressure being measured by the pressure transducer. This will normally be the 2-3
of the Press (Set Pressure).