Type of printhead, Reference pressure and Reference VOD that can’t be edited directly. Their
values are decided by the value of printhead code.
5.1.1.
Printhead Height
The jet must be stopped to set up this option. As for printhead to printer cabinet height,Pressure
varies by 5 units for every meter. Printhead Height can set up from the value between -9.5 and
+9.5 meters.However, printheads are currently a maximum of 6 meters in length, so the maximum
value here should be 6.0. For brevity , the installation height of printhead relative to Printer is
calculated by half a meter or one meter. If the printhead is mounted below the printer, the value
should be inputting the following format -X.Xm. If the printhead is mounted above the printer, it
is not necessary to place + in front of the value. The value may be entered simply as -X.Xm.
NOTE: Be carefully when setting this option; poor printer performance will result if incorrectly
set.
The printer will automatically change the pressure reference according to inputed printhead
height.In the menu you can see the calculated solvent- added- pressure
5.1.2.
Modulation Settings
Set the referance modulation voltage value
5.1.3.
Conduit Length
Restart the printer after changing the new printhead. The system will detect the length of new
printhead conduit automatically.
5.2.
Alarm Output
The printer offers three-way relay output. Each way is dynamic contact, that is contact closes
when action. It can control current circuit of the voltages under 60V and the current under 1A. It
usually controls the outside alarm indicator light. You need to offer extra power supplier to outside
alarm indicator light. Don’t want to get power supply from the printer.
Four modes of alarm signal:
1. Pulse output: Contact pulse closes twice during alarm occurring.
2. Continuous output: Contact close continuously during alarm occurring.
3. Continuous pulse output: Contact pulse close during alarm occurring.
4. No output: No action on contact.
Summary of Contents for EC-JET 2000
Page 14: ...User Manual The1 1 version of 2018 Guangzhou EC PACK CO LTD 14 ...
Page 76: ...User Manual The1 1 version of 2018 Guangzhou EC PACK CO LTD 76 ...
Page 91: ...User Manual The1 1 version of 2018 Guangzhou EC PACK CO LTD 91 ...
Page 107: ...User Manual The1 1 version of 2018 Guangzhou EC PACK CO LTD 107 Appendix 4 Dimension ...