![Eaton UltraShift PLUS Series Service Manual Download Page 97](http://html1.mh-extra.com/html/eaton/ultrashift-plus-series/ultrashift-plus-series_service-manual_4150397097.webp)
2018.12.12
© 2017 Eaton. All rights reserved
86
TRSM0940
Service Procedures
|
MHP/MXP/VHP/VXP Auxiliary Section Removal and Disassembly
14.
Remove the Auxiliary Counter Shaft Bearing Races
from their bores.
15.
If necessary, secure the Countershafts in a vise and
remove both the front and rear bearings from the
shafts with a bearing separator and jaw pullers.
16.
Remove the 15/16” cap screw and retainer bolt that
was loosened in step 9
17.
Remove the splitter gear from the Output Shaft
Note:
For disassembly and assembly of the Splitter
Gear assembly, please refer to the “Splitter Gear Bear-
ing Disassembly and Assembly – MHP, MXP, VHP,
VXP” section