LAS/VAS Auxiliary Section Assembly and Installation
8
.
Place the Auxiliary Case over the Main Shaft/Counter
Shaft assembly.
9.
Install the upper and lower Counter Shaft Rear Bearing
Races into the Auxiliary Case.
10.
Install the Auxiliary Counter Shaft Support Straps to
hold the Counter Shafts in place.
Note:
Hold the Counter Shafts from spinning while
tightening Auxiliary Counter Shaft Support Straps, fail-
ure to do this could allow Counter Shafts to come out
of time with the Range Reduction Gear.
11.
Place the outer Auxiliary Shaft Bearing over the shaft
with the tapered side down (short rollers), drive into
place using the Output Shaft Bearing Driver.