TRSM0940
Service Procedures
|
MHP/MXP/VHP/VXP Splitter Cylinder Disassembly and Assembly
4.
Position new gasket on the Cylinder Housing, and
install the Splitter Cylinder
5.
Install O-Ring on the end of the yoke bar inside of the
Cylinder Housing
6.
Install the O-ring on the ID and OD of the piston.
7.
Install Piston into the bore of the Range Cylinder Install
with the flat side of the piston facing rearward.
8
.
Position new gasket on the Cylinder Housing Cover
mounting surface and install the Splitter Cylinder Cover
Note:
Ensure that the gasket air passage aligns with
the housing air passage