85
© 2017 Eaton. All rights reserved
2018.12.12
MHP/MXP/VHP/VXP Auxiliary Section Removal and Disassembly
|
Service Procedures
TRSM0940
10.
Loosen the 15/16” cap screw and retainer on the Out-
put Shaft. Do not remove the cap screw.
Note:
To prevent the counter shafts from turning, place
a shop rag or equivalent between the splitter gear and
one counter shaft.
11.
Using a soft bar and maul, drive the Output Shaft for-
ward far enough to partially unseat the bearing.
12.
Support the Auxiliary Countershaft and remove the
strap from the rear of the Auxiliary Case Housing
13.
Repeat process to remove 2nd Auxiliary Counter Shaft.