2018.12.12
© 2017 Eaton. All rights reserved
14
TRSM0940
Service Procedures
|
LAS/VAS Auxiliary Section Removal and Disassembly – In Chassis
In Chassis
1.
Drain the oil.
2.
Disconnect the OEM supplied air line. (Refer to Air Line
disconnection for the procedure.)
3.
Disconnect the driveline a move out of the way.
4.
Disconnect the Wiring Harness from the Range Sole-
noid Valve and speed sensor.
5.
If any OEM equipment needs to be removed refer to the
OEM for guidelines.
6.
Remove the 19 bolts securing the Auxiliary Section to
the Transmission.
7.
Put the removal jack in place and secure to the Auxil-
iary Section.
8
.
Slowly remove the Auxiliary Section from the Main
Case and the dowel pins.
9.
Once the Auxiliary Section is on the bench, go to
LAS/VAS Auxiliary Section Removal and Disassembly
on page 15.