TRSM0940
Service Procedures
|
VCS/VMS Auxiliary Section Removal and Disassembly
Auxiliary Mainshaft Assembly Disassembly
1.
Remove the bearing inner spacer from the Output
Shaft
2.
Using the Deep Reduction Gear front as a base, press
the Output Shaft through the bearing and gear.
Note:
If reusing the bearing set, the tapered roller bear-
ings are specific to each side of the race.
3.
Remove the spacer and stepped washer from the Deep
Reduction Gear