TRSM0940
Service Procedures
|
LAS/VAS Auxiliary Section Removal and Disassembly
4.
Apply downward pressure to the High Range Synchro-
nizer Ring while twisting counterclockwise to com-
press the springs and fully seat the ring on the Blocker
Pins of the Low Range Synchronizer.
5.
Install the Synchronizer assembly on the splines of the
Auxiliary Main Shaft with the Synchronizer seated
against the Range Reduction Gear.