Shift Bar Housing Removal and Installation
|
Service Procedures
TRSM0940
Shift Bar Housing Removal
1.
Remove the 16 cap screws and studs fastening the
Shift Bar Housing to the Transmission Case. Remove
the Shift Bar Housing.
Shift Bar Housing Installation
1.
Ensure all Transmission Main Case Main Shaft Sliding
Clutches are in their Neutral position.
2.
Ensure that the Main Case and Shift Bar Housing gas-
ket surfaces are clean and free of debris.
3.
Position a new Shift Bar Housing gasket on the surface
of the main case.
4.
Install the Shift Bar Housing onto the Transmission
Main Case.
5.
Install the 16 cap screws that fasten the Shift Bar
Housing to the Transmission Main Case. Torque cap
screws to 35–45 lb-ft.